This specification covers the general requirements for UTP cable used for outdoor and indoor installation (remove the outer jacket for indoor installation) LINK Ultra Category 6 U/UTP outdoor double jacket with drop wire cables compliant ISO/IEC 11801 Class E and ANSI/TIA-568.2-D requirements for category 6 performance. These cables are characterized to 600MHz, Powersum NEXT tested certified. The cables are designed for outdoor aerial installation with drop wire for CCTV systems or other.
Conductor Material: Solid bare copper
No. of Conductor: 4 Pairs
Conductor Diameter: 23 AWG
Insulation Material: High Density Polyethylene
Insulation Diameter: 1.00 ± 0.05 mm
Rip Cord: Under Jacket
Filler Slot Material: FRPE
Drop Wire Material: Galvanize Steel Wire
Drop Wire Diameter: 1.30 ± 0.10 mm
Inner Jacket Material: FR-PVC
Inner Jacket Thickness: 0.51 ± 0.50 mm
Inner Jacket Diameter: 6.10 ± 0.20 mm
Outer Jacket Material: UV-Proof, PE
Outer Jacket Thickness: 0.51 ± 0.50 mm
Outer Jacket Diameter: 7.40 ± 0.20 mm
Flame Rating: CMX
Impedance: 100 ± 15 Ω, 1 MHz to 600 MHz
Capacitance: ≤ 5.6 nF Max / 100m
Unbalance Capacitance: ≤ 160 pF Max / 100m
DC Resistance: ≤ 6.65 Ω Max./100m
Unbalance DC Resistance: ≤ 2.5% Max
Dielectric Strength: ≤ 1 kV/min
Insulated Resistance: ≥ 5000 MΩ/km
AC leakage current through overall jacket: ≤ 10mA
Spark Test: 2.5 kV DC
Propagation Delay: ≤ 536 ns/100m Max @600MHz
Delay Skew: ≤ 30 ns Max
NVP: 69%
Tensile Strength: 110 N 16.5 MPa
Ultimate Breaking Strength: >400 N
Min. Bending Radius Operation: 4 X Cable Diameter
Min. Bending Radius Installation: 8 X Cable Diameter
Operating Temperature: -40°C to 75° C
Storage Temperature: -40°C to 80° C
Color: Black
Dimensions:
-Cable length: 100M
No. of Conductor: 4 Pairs
Conductor Diameter: 23 AWG
Insulation Material: High Density Polyethylene
Insulation Diameter: 1.00 ± 0.05 mm
Rip Cord: Under Jacket
Filler Slot Material: FRPE
Drop Wire Material: Galvanize Steel Wire
Drop Wire Diameter: 1.30 ± 0.10 mm
Inner Jacket Material: FR-PVC
Inner Jacket Thickness: 0.51 ± 0.50 mm
Inner Jacket Diameter: 6.10 ± 0.20 mm
Outer Jacket Material: UV-Proof, PE
Outer Jacket Thickness: 0.51 ± 0.50 mm
Outer Jacket Diameter: 7.40 ± 0.20 mm
Flame Rating: CMX
Impedance: 100 ± 15 Ω, 1 MHz to 600 MHz
Capacitance: ≤ 5.6 nF Max / 100m
Unbalance Capacitance: ≤ 160 pF Max / 100m
DC Resistance: ≤ 6.65 Ω Max./100m
Unbalance DC Resistance: ≤ 2.5% Max
Dielectric Strength: ≤ 1 kV/min
Insulated Resistance: ≥ 5000 MΩ/km
AC leakage current through overall jacket: ≤ 10mA
Spark Test: 2.5 kV DC
Propagation Delay: ≤ 536 ns/100m Max @600MHz
Delay Skew: ≤ 30 ns Max
NVP: 69%
Tensile Strength: 110 N 16.5 MPa
Ultimate Breaking Strength: >400 N
Min. Bending Radius Operation: 4 X Cable Diameter
Min. Bending Radius Installation: 8 X Cable Diameter
Operating Temperature: -40°C to 75° C
Storage Temperature: -40°C to 80° C
Color: Black
Dimensions:
-Cable length: 100M